Rss

JEREMY W

Not Listed

Occupation:

Not Listed

Education Level:

Associate

Will Relocate:

YES

CollapseDescription

Experienced with American National Standards Institute (ANSI) regulations for implementation of these plans and for appropriate safeguarding of employees through proper personal protective equipment (PPE) selection. - Identified, procured, and delivered appropriate PPE. - Provided on-site safety and compliance audits for ongoing MTS, LLC projects and concerns. - Provided OSHA-regulated recordkeeping (300 series forms) for all MTS, LLC projects. - Implemented behavior-based safety observation and near miss reporting system. - OSHA CFR 1910, CFR 1926, HAZWOPER, HAZCOM/GHS and Radiation Safety Officer certified. - Familiar with USACE EM 385-1-1 Safety and Health Requirements Manual requirements - Developed and implemented quality control programs and strategies. USACE CQM-C certified. April 2014 - October 2015 - Regional Manager, Hydraulic Fracturing Electronics Systems, Archer Pressure Pumping, LLC (APP, LLC), Oklahoma City, OK - Responsible to the President of APP, LLC for the management and safe operation of all electronics communications, controls, SCADA, integrated systems, and information technology systems for 5 mobile, hydraulic fracturing fleets across 2 different geographic regions/districts. Total value of equipment is estimated at > $150MM. Manage a departmental budget of $3.75MM annually. - Managed, trained, and developed 28 technicians who support these fleets remotely. Maintained these technicians 100% preventable accident-free. - Integrated multiple (7) control systems for safe operation and remote control of high pressure pumping, capital equipment. - Identified training and developmental shortcomings of personnel and implemented training plans, evaluation formats, and operations directives for a marked improvement in performance and service quality to our customers. - Developed and implemented preventative maintenance plan (PM) system for electronics maintenance, a system which was not in existence prior to my arrival. The implementation of this plan reduced corrective maintenance costs by 60%, and allowed for documentation and fault and trend analysis for all equipment owned by APP, LLC. Managed 99% uptime on all equipment. - Managed and implemented fleet-wide software upgrade integration to increase fleet versatility, increased pressure handling capability, and operator safety, ultimately enabling the Company to pursue a new, more lucrative business market segment and increase overall Company profitability. - Researched and integrated new VSAT satellite communications provider for APP, LLC at 50% cost savings per month and transitioned the new provider and equipment seamlessly and with ZERO outages during transitional phase. Concurrently provided safety and security measures by integrating VoIP phone service for 100% reliable communications in remote service locations. - Developed and rolled out a Technical Bulletin system to document complex technical operations for field technician guidance and support. - Embraced and embodied a lean operating philosophy. Saved the Company ~ $300,000 in repair/ maintenance for electronic systems across Q2 2014 - Q3 2015. Also provided measureable cost reduction in maintenance consumables (grease, etc) for "sister" maintenance division. - Certified Radiation Safety Officer (RSO). Manage safe handling of over 30 radioactive sources company-wide. - Professionally interface daily with APP, LLC support team entities and supply chain, external customers and vendors, and corporate level management team. - Interfaced with supply chain management to identify and implement cost - savings initiatives for repair parts, consumables, and front line equipment. Experienced with SAP, Maintenance Assistant, and GoToMeeting/Citrix for accounting and maintenance tracking/planning. Familiar with JD Edwards accounting software and Kronos Workforce Ready timeclocks. July 2013 - 2015 Senior Energy & Control Systems Consultant, Iron Wind, LLC, Stafford, VA. - Provided professional consulting services for a developing 8A government contractor specializing in complex problem solving for government and commercial, maritime, and terrestrial interests. - Assigned industrial communications tasking including the interface of SCADA to J1939 data bus onboard commercial cargo vessels. - Familiar with Predictive Emissions Monitoring Software models and installation. - Rockwell Automation Pavilion software subject matter expert - Subject Matter Expert with Wartsila, Caterpillar, Rolls Royce, Cummins, and MTU diesel engine control systems and interfaces for both terrestrial and marine applications. Experienced with job cost and production analysis, bidding, and contract negotiation. Experienced with OSHA requirements in a heavy industrial environment. - Operated multiple types of construction/heavy equipment including hydraulic excavators, bulldozers, loader/backhoes, forklifts, and skid loaders. Performed as a "working superintendent". Familiar with every process of residential and multi-family residential construction. - Freelance building superintendent/consultant. Managed up to 20 separate construction and remodeling projects simultaneously. Project values ranged from $3,000 - $110,000. All projects under my cognizance were finished within schedule and within 10% of proposed budget. August 2003 - October 2004 Strategic Communications and Mission Avionics Instructor/Project Specialist, Long Wave, Inc., Oklahoma City, OK/Tinker AFB. - Designed, developed, implemented, and delivered electronic communications training scenarios and classroom curriculum for certification of military communications specialists carrying out duties crucial to National Security. LongWave, Inc is a HUB-Zone business entity specializing in radio frequency propagation systems and antennas, program management, and training for US Navy airborne communications teams. - Assisted in the integration of proprietary software and hardware interface systems into existing voice and data communications systems. - Researched, developed, and implemented practical methods to improve communications training, operations, and effectiveness. Advised US Navy officials on the correct selection, deployment and use of electronic communications equipment in the Very Low Frequency (VLF) to Extremely High Frequency (EHF) range. - Maintained records to document the enhanced performance of students once they enter the Fleet (work force). Realized, on average, a 20% increase in performance and certifications as documented in a recent global exercises. December 1987 - July 2003 Electronics Integrated Systems Mechanic (Project Lead Mechanic) (WG-12), Department of the Navy, Civil Service. Ohio and Ben Franklin (Class) Submarine Communications Electronics Technician (Leading Petty Officer/Supervisor), United States Navy, Active Duty, Silverdale, WA. - Operated and employed test equipment including digital multi- meters, oscilloscopes, signal generators, sweep oscillators, network analyzers, power meters, purified nitrogen vacuum/pressurization rigs, and recording devices for troubleshooting and repair procedures. Performed insertion loss, amplifier gain, and standing wave ratio tests on Radio Frequency transmission media including wave guides, semi-rigid, and coaxial lines. - Maintained and repaired integrated systems for the AN/BSC-1 EHF Submarine Communications suite and the AN/WLR-8 Electronic Countermeasures system. Responsible for the efficiency and mission readiness of the entire Forward Electronics Suite, including masts and antennas, periscopes, and overall combat systems integration. - Maintained equipment and materials, within budget, for two separate divisions. Managed up to 12 technicians in the performance of their duties. - Developed and implemented training plans, safety standard operating procedures (SOP), equipment operating procedures, and subordinate development and qualifications plans by insightful and conscientious application of 15 years of submarine communications experience and training. - Delivered in excess of 4,000 hours of classroom, practical lab and team building instruction. Instruction was given to multi-demographic, multi-discipline class composition. - Read and interpreted electronic, hydraulic, and pneumatic schematic diagrams as well as technical manuals, specifications, and drawings to complete repairs to equipment from component to system level. - Yearly top 10 % performer every year of Federal service since 1990.

Right_template4_bottom

CollapseAccomplishments

Highlights:

Left_template4_bottom

CollapseKeywords

Left_template4_bottom